MOM 6.2.10

15.6. Example 6: Common simulation with a coaxial feed source

This case explains how to calculate far-field, radiation pattern, current density, charge density, near field and impedance of an open box with a coaxial feed simple blade insides the box.

 

Step 1: Create a new MOM Project.

Open 'New Fasant' and select 'File --> New' option.

Figure: New Project panel

 

Select 'MOM' option on the previous figure and start to configure the project.

 

Step 2: Create the geometry model. To obtain more information about geometries generation see section 4. Geometry Menu on GUI User-Guide.

Execute 'box' command writing it on the command line and sets the parameters as the next figure shows when command line ask for it.

 

Figure: Box parameters

 

Select box geometry on main panel and execute 'explode' command writing it on the command line. Then the box will be transformed into 6 surfaces.

 

Figure: Box selection and 'explode' command

 

Select the top surface and execute 'delete' command. Then the surface will be removed from the geometry.

 

Figure: Surface selection and 'delete' command

 

Select all remaining surfaces and execute 'group' command.

 

Figure: Surfaces selection and 'group' command

 

Step 3: Set Simulation Parameters

Select 'Simulation --> Parameters' option on the menu bar and the following panel appears. Set the parameters as the next figure shows and save it.

 

Figure: Simulation Parameters panel

 

Step 4: Set the source parameters. To obtain more information about sources and antennas see Antennas User-Guide.

Select 'Source --> Primitive Antenna --> Coaxial Feed --> Blade --> Simple Blade' option and set the parameters as show the next figure. Then save the parameters and the antenna appears.

 

Figure: Simple Blade Antenna panel

 

Step 5: Set Near Field parameters.

Select 'Output --> Observation Points' option. The following panel will appear.

 

Figure: Observation Points panel

 

To add a line visualization, select 'line' on the selector of 'Geometry Types' section and click on 'Add' button. The line parameters panel will appear, then configure the values as the next figure show and accept it clicking on 'OK' button.

 

Figure: Observation Line panel

 

The observation line will appear as a dashed line on the position configured.

 

Figure: Observation Line visualization

 

Step 6: Meshing the geometry model.

Select 'Meshing --> Parameters' to open the meshing configuration panel and then set the parameters as show the next figure. In order to obtain the shortest possible time for meshing, it is recommended to run the process of meshing with the number of physical processors available to the machine.

 

Figure: Meshing panel

 

Then click on 'Mesh' button to starting the meshing. A panel appears to display meshing process information.

 

Figure: Meshing process log

 

Step 7: Execute the simulation. In order to obtain the shortest possible time for calculating the results, it is recommended to run the process with the number of physical processors available to the machine.

Select 'Calculate --> Execute' option to open simulation parameters. Then select the number of processors as the next figure show.

 

Figure: Execute panel

 

Then click on 'Execute' button to starting the simulation. A panel appears to display execute process information.

 

Figure: Execute process log

 

Step 8: Show Results. To get more information about the graphics panel advanced options (clicking on right button of the mouse over the panel) see Annex 1: Graphics Advanced Options on GUI User Guide.

Select 'Show Results --> Far Field --> View Cuts' option to show the cuts of the observation directions options.

 

Figure: Far Field cuts

 

Selecting other values for the component, step, frequency or cut parameters and clicking on 'Add Series' button a new cut will be added to the selected parameters.

On 'Show Results --> Far Field' menu, other results are present such as 'View Cuts by Step' and 'View Cuts by Frequency' and this option display the values for one selected point for each step or frequency.

 

Select 'Show Results --> Radiation Pattern --> View Cuts' option to show the cuts of the radiation pattern options.

 

Figure: Radiation Pattern cuts

 

Selecting other values for the component, step, frequency or cut parameters and clicking on 'Add Series' button a new cut will be added to the selected parameters.

On 'Show Results --> Radiation Pattern' menu, other results are present such as 'View Cuts by Step' and 'View Cuts by Frequency' and this option display the values for one selected point for each step or frequency.

 

Select 'Show Results --> Radiation Pattern --> View 3D Pattern' option to show the cuts of the radiation pattern options.

 

Figure: Radiation Pattern 3D

 

Changing values for step, frequency, component or filtering parameters the visualization for the new parameters will be shown.

 

Select 'Show Results --> View Currents' option to show the current density.

 

Figure: Current Density

 

Changing values for step, frequency, magnitude, component or filtering parameters the visualization for the new parameters will be shown.

 

Select 'Show Results --> View Charges' option to show the charge density.

 

Figure: Charge Density

 

Changing values for step, frequency, magnitude or filtering parameters the visualization for the new parameters will be shown.

 

Select 'Show Results --> Near Field --> View Near Field Diagram' option to show the observation points diagram. Previously, select the observation to visualize and the step and frequency on the next figure.

 

Figure: Near Field diagram selection

 
 

Figure: Near Field diagram

 

Changing values for incidence, magnitude, field or component parameters the visualization for the new parameters will be shown.

 

Select 'Show Results --> Near Field --> View Observation Points' option to show the observation points chart.

 

Figure: Near Field Observation Points cuts

 

Selecting other values for incidence, component, step, frequency or observation parameters and clicking on 'Add Series' button a new cut will be added to the selected parameters.

On 'Show Results --> Near Field' menu, other results are present such as 'View Cuts by Step' and 'View Cuts by Frequency' and this option display the values for one selected point for each step or frequency.

 

Select 'Show Results --> View Impedance' option to show the impedance values for the simulated coaxial feed.

Figure: Impedance panel

 

Selecting other values for the step or return loss parameters new values will be displayed for the selected parameters.

Clicking on 'Chart' button when any columns selected on 'Results' table, a plot with the values will be opened.

Figure: Impedance chart

 

We use cookies on this website to improve your navigation experience on this site. By using this site, you agree to our cookie policy.